NEW QUESTION # 157
UPS5000-E has the industry-leading reliability design, then the following is correct about the reliability design of UPS5000-E ( ).

  • A. 40 degrees without derating
  • B. The veneer is reinforced with conformal paint
  • C. More than 1400 test guarantees
  • D. Strong grid adaptability, voltage input range of 138-485V

Answer: A,B,C,D


NEW QUESTION # 158
The high input power factor of the UPS indicates that the UPS has a strong ability to effectively utilize the power grid and a weak ability to interfere with the power grid. The input power factor of UPS2000-A-(1K-3K) is ( ).

  • A. 0.95
  • B. 0.85
  • C. 0.99
  • D. F0.9

Answer: C


NEW QUESTION # 159
The NetEco management system can provide the temperature cloud map function, which is used to monitor the temperature distribution in the computer room and quickly identify the hot spots in the computer room.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 160
Huawei NetGol (35KW) in-row air conditioner adopts wet film humidification function ( )

  • A. True
  • B. False

Answer: A


NEW QUESTION # 161
The biggest difference between the operation and operation and maintenance modules defined by NetEco is that operation mainly focuses on efficiency, benefit, and experience, facing business, service, and customers, while operation and maintenance focus on stability, reliability, security, and infrastructure. software and hardware. ( )

  • A. True
  • B. False

Answer: A


NEW QUESTION # 162
The NetEco V6R8 version of the data center management system can support the access of up to 100,000 measuring points on a single server.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 163
FusionModule800 connecting pipes within 30m does not need to charge refrigerant on site?

  • A. True
  • B. False

Answer: A


NEW QUESTION # 164
The FusionModule2000 integrated power distribution cabinet has two input switches of single-channel MCCB and ATS.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 165
FusionModule1000A V2R3 version 20 feet CT scene air conditioning features are (multiple choice)

  • A. Water cooling
  • B. Direct Expansion Refrigeration
  • C. Air cooling
  • D. Inverter compressor
  • E. Free cooling technology

Answer: B,C,D


NEW QUESTION # 166
Which of the following models has the widest input voltage range and is more suitable for harsh power grids?

  • A. UPS5000-A
  • B. APC Galaxy7000
  • C. Eaton 9395
  • D. Emerson NXF

Answer: A


NEW QUESTION # 167
High-rate batteries have advantages in short-time discharge, and can discharge up to 90%.

  • A. True
  • B. False

Answer: A


NEW QUESTION # 168
The NetEco6000 management system can manage the devices inside the FusionModule and outside the module at the same time.
In the default recommended solution, the devices inside the FusionModule use the ( ) collector to access the device, and the devices outside the module use the ( ) collector. to access the device?

  • A. ECC500, ECC800
  • B. ECC800, ECC800
  • C. ECC500, ECC500
  • D. ECC800, ECC500

Answer: D


NEW QUESTION # 169
Which of the following functions need corresponding hardware support? ( )

  • A. Battery Management
  • B. Power distribution links.
  • C. U bit self-identification
  • D. Temperature cloud map

Answer: A,C,D


NEW QUESTION # 170
What factors are currently affecting the application of HVDC equipment in the computer room? ( )

  • A. The efficiency is too low
  • B. The standard is not perfect, and multiple standards of 240V/336V coexist.
  • C. Not all loads can be directly powered by DC
  • D. Higher cost of DC switching devices

Answer: A,B,C,D


NEW QUESTION # 171
In FusionModule2000, how to adapt the skylight when the column occupies the closed passage space in the scene around the column?

  • A. On-site cutting with plexiglass adjustable skylight
  • B. Customized tempered glass flip skylight
  • C. Sealed with special adjustable sealing plate for skylight
  • D. Field machining with control skylight

Answer: C